Q.1
14 MarksClear Cover, Effective Cover and Partial Safety Factor.
Explain briefly about Under reinforced section, Balanced section and Over reinforced section.
Also asked in Summer 2023 Q2b
Noted. This paper is in our queue now. Check back tomorrow.
We could not record that here. Email the paper name to hirenjsca@gmail.com and we will add it.
4 of 25 questions on this paper were also asked in other years. 4 more are types of question GTU sets again with new data. Each is marked below with the years it appeared.See all 27 repeated 3150612 questions, most asked first
Clear Cover, Effective Cover and Partial Safety Factor.
Explain briefly about Under reinforced section, Balanced section and Over reinforced section.
Also asked in Summer 2023 Q2b
Discuss the assumptions made in the limit state design of reinforced concrete compression members.
An R. C. C. beam of size 350 wide and 550mm deep is reinforced by tension bars as 5nos. of 25mm dia. and compression bars as 3nos. of 20mm dia. Calculate the moment of resistance of beam if the clear cover is 25mm on both the sides.
Also asked in Winter 2025 Q1c, Summer 2024 Q1c, Summer 2023 Q1c
Also discuss the merits and demerits of each.
A 4m high column is effectively held in position at both ends and restrained against rotation at one ends. Its Diameter is resisted to 40 cm. Calculate the reinforcement if it is required to carry a factored axial load 1600 kN.
Design an Isolated square footing for square column of 450 mm x 450 mm For axial load of 840 kN. Take SBC of soil 100kN/m². Draw all necessary sketches.
Also asked in Summer 2026 Q5b OR, Summer 2025 Q3b, Summer 2024 Q3b
Determine Bolt value of 20 mm diameter bolt connecting 10 mm plates in :
Also asked in Summer 2025 Q2c, Summer 2024 Q2c, Summer 2023 Q2c
Design a simply supported beam of span 5 m subjected to working dead load of 24kN/m and Live load of 13 kN/m. The beam is laterally unrestrained. Check for deflection is not required
Also asked in Summer 2026 Q4a, Summer 2023 Q5a
An ISA 150x75x10 mm is subjected to axial tensile force of 190 kN connected by its longer leg to 10 mm thick gusset plate. Design welded connection for shop welding.
Also asked in Summer 2026 Q2c OR
Also asked in Winter 2025 Q3a OR, Summer 2025 Q3a, Summer 2023 Q3a
Design a simply supported one way slab 3m x 7m supported on 300 mm wide beams. The slab carries a 2 kN/m² live load and 1.2 kN/m² finish load. Check criteria for deflection and development length.
Also asked in Summer 2026 Q3c, Summer 2023 Q5c
Give Codal provisions for development length, Bond Stress , Anchoring reinforcement.
Determine the design axial compressive load on the given column section ISMB 450 @ 72.4 kg/m having length 4 m between the intersections and pined at the ends. Take fy 250 MPa.
Sketch reinforcement detail for a simply supported one-way square slab showing all required details including torsion reinforcement.
Design a slab base for a built up column composed of 2 channel sections ISMC 300 placed back to back at clear spacing 200 mm Axial factored load on column is 850 KN and SBC of soil is 175 KN/m².
Questions repeat across sessions. Working through two or three papers shows you which topics GTU asks most.
BE Civil
Send this paper to your class group. Every question has its own link.
Official Gujarat Technological University (GTU) examination paper for Design of Structures (Winter 2023, B.E. · Civil Engineering, Sem 5). Features complete 70-mark regular & remedial examination pattern, official marking distribution across all 5 questions, and direct 1-click official PDF download.
Transcribed for student exam preparation from Gujarat Technological University official examination archives. Questions, syllabus guidelines, and curriculum marking schemes remain the intellectual property of Gujarat Technological University.
3150612 Design of Structures
Official GTU PDF · Winter 2023
The PDF could not be loaded from the university's website.
Open the PDF directly